Siedle Installation Guide 2-Wire Bus - Siedle USA

advertisement
Planning Manual
Siedle In-Home bus
Issue 2011
Contents
General
Siedle In-Home bus
3
Fields of application
4
Performance features
4
Components and users
5
Siedle In-Home bus General
6
Procedure during planning
7
Siedle In-Home bus: Audio
Ranges and system limits
Single line system
Ranges and system limits
Multiple line system
8
9
Single line system up to max. 31 users
Cable size diagram
10
Multiple line system up to max. 465 users
Cable size diagram
11
Installation notes
12
Siedle In-Home bus: Video
Ranges and system limits
13
Single line system up to max. 31 users
Cable size diagram
14
Multiple line system up to max. 465 users
Cable size diagram
15
Installation notes
Range
Attenuation values
System limits
16-19
Example for calculating attenuation
20
Storey door station at the In-Home bus: Audio
Storey door station at the In-Home bus: Video
21
Switching and control functions
at the Siedle In-Home bus
22
Siedle In-Home bus combined with Vario bus
Ranges in the Vario bus
Input module at the Vario bus
23
Device description
Door area
•Vario door station
•Bus custom-fit door loudspeaker
•Siedle Classic
•Select door station
24-25
Cameras
26-27
Bus telephones Audio
28
Accessories
29
DoorCom-Analog
DoorCom IP In-Home
30
Bus telephones Video
31
Accessories
Bus secondary signal unit
32
Power supply In-Home bus
Space requirement in the distributor
33
Switching and control devices
Bus distributor
34
Vario bus Switching and control devices
Information on programming
35
Siedle exhibition centres
39
Please note:
For complex systems or special
requirements, the technical
consultants in our centers will
be pleased to advise you.
Technical additions or printing errors do not constitute
grounds for compensation
claims.
Siedle In-Home bus
The Siedle In-Home bus is a
high-performance communication system with a wide range
of performance features which
is simple to set up.
The basic functions calling,
speech, door release and light
switching are supplemented by
video and control functions.
Interfaces to the telephone
network are available with the
DoorCom family for analogue
and ISDN connection.
From small-scale systems in
the sophisticated single family
home through multiple family
homes to large residential complexes, the Siedle In-Home bus
is in popular use as a communication and control system.
The entire range of functional
features is available if just 2
adjacent YR wires are available
throughout the system.
For newly installed systems,
we recommend using standard
commercially available conductor material J-Y(ST)Y.
Every user connected to the
In-Home bus is able to fulfil its
intended function independently of where it is installed.
The functions can be modified
and adjusted by programming.
BTC 850
BTC 850
BTC 850
BTC 850
BFS 850
BTC 850
BTS 850
BTC 850
BTS 850
BFC 850
BTS 850
BFS 850
BTS 850
BFS 850
BFS 850
BTS 850
BFC 850
BTS 850
BFC 850
BFC 850
BNG 650
Door station
In-Home bus: Audio
as a single-line system
Tö
BNG 650
BNG 650
Door station
Tö
Door station
Tö
BNG 650+
ZBVG 650
BNG 650
Door station
Tö
In-Home bus: Audio
as a multiple-line system
3
Siedle In-Home bus
Fields of application
The only requirement for use
of the Siedle In-Home bus are
2 continuous YR or J-Y(St)
Y cores, via which the entire
range of functions including
audio and video communication can be performed.
The Siedle In-Home bus is used
• in sophisticated one and
two-family homes which seek a
greater level of operating convenience using the increasingly
accessible technical possibilities
available
• in multiple family homes and
larger residential complexes
offering an enhanced level of
security
• and in private and commercial properties in which additional control and switching
functions are required
Performance features
Performance features
Siedle In-Home bus with BTS/
BFS/BTC/BFC/BTSV/BFSV/BTCV/
BFCV 850-..., S 850-...
Performance features
Siedle In-Home bus with BTS/BFS/
BTC/BFC/BTSV/BFSV/BTCV/
BFCV 850-..., S 850-...
Calling/speech/door release/audio
privacy function storey call with call differentiation
•
Digital call input possible (COM/DRM)
• BIM 650-... required
Parallel door call
• Up to 4 users
Light control
without additional installation
extendable to 8 devices with additional
power supply
BTC/BFC/BTSV/BFSV/BTCV/BFCV 850-...,
S 850-...
Secondary signal unit
via BNS 750-... or standard commercially available signal unit via BSM/
BSE 650-... or ZAR/ZARF 850-...,
additional installation required
Doormatic function
BTC/BFC/BTCV/BFCV 850-..., S 850-...
Call forwarding
BTC/BFC/BTCV/BFCV 850-..., S 850-...
Send internal group call
BTC/BTCV/BFC/BFCV 850-..., S 850-...
Receive collective paging
announcement
BFC/BFCV 850-...
Automatic call pickup of internal calls
BFC/BFCV 850-...
Programming
manual, Plug+Play* or via PC
Door release time
fixed at 3 secs
No. of door stations
within the system limits optional
number
Number of lines
max. 15
Number of users per line
max. 31
Total number of users
max. 465
Speech circuits
1 per line
Call silencing with LED display
•
Call volume control in 5 steps
•
Video link
via BTSV/BFSV/BTCV/BFCVВ 850-...,
S 850-...
Storey door loudspeaker with call
differentiation
•
Internal communication including call
progress tones
•
Switching/control function
•
Display LEDs under the buttons
• BTC/BFC/BTCV/BFCV 850-..., S 850-...
Direct selective door dialling including
video actuation
• BTSV/BFSV/BTCV/BFCV 850-...,
S 850-...
11 call signals, including chime
•
(* ZPS/ZPSF 850-… required)
Plug+Play programming
exclusively using the devices of
series:
• BTS/BFS/BTC/BFC/BTSV/BFSV/
BTCV/BFCV 850-..., S 850-...
• BNG/BVNG 650-... and
• BTLM 650-03 with
BTM 650-01 to BTM 650-04 or
• BTLE 050-03 with
BRMA 050-01
• Siedle Classic CL xx B 01
• Select door station audio/
video STA/STV 850-1 -2 or -4
• Siedle Steel with
SBTLM 650-03
When using in a mixed installation with predecessor models,
Plug+Play programming is not
possible.
Applies for the assignment of
call stations to call buttons.
Extensions to the basic functions, for example parallel
call or switching and control
functions, are additionally programmed manually or by PC.
Components and users
Area
Components
Users
Area
Components
Door area
BTLM/SBTLM 650-...
Bus door loudspeaker module
2
Distribution
BNG 650-...
Bus line rectifier (for audio)
-
BCMC 650-...
Bus colour CCD camera
module
-
ZBVG 650-...
Bus supply unit accessory
-
BVNG 650-...
Bus video line rectifier
-
BTLE 050-...
Bus-custom-fit door
loudspeaker
2
ZBVNG 650-...
Bus video line rectifier
accessory
-
CL 01 B-01
Classic door station bus
2
BAA 650-...
Bus audio decoupler
-
STA/SBA 850-...
Select door station audio
2
BVVU 650-...
-
STV/SBV 850-...
Select door station video
2
Bus video distributor asymmetrical
BTM 650-...
Bus call button module
-
BVVS 650-...
-
BRMA 050-...
Bus call button matrix
-
Bus video distributor symmetrical
BVA 650-...
Bus video interfacing module
2
BSM 650-...
Bus switching module
1
BIM 650-...
Bus interface module
-
BSE 650-...
Bus switching unit
1
BEM 650-...
Bus input module
1
Living area
BVS 650-...
Bus video transmitter
-
BTS 850-...
Standard bus telephone
1
BFS 850-...
Standard handsfree bus
telephone
1
BTC 850-...
Deluxe bus telephone
1
BFC 850-...
Deluxe handsfree bus
telephone
1
BNS 750-...
Bus secondary signal unit
1
BTSV 850-...
Standard bus telephone with
color monitor
1
BFSV 850-...
Standard handsfree bus
telephone with color monitor
1
BTCV 850-...
Deluxe bus telephone with
color monitor
1
BFCV 850-...
Deluxe handsfree bus
telephone with color monitor
1
S 850-...
Siedle Scope cordless DECT
telephone with door video
function
1
Interface to the telephone network
Area
Components
Users
DCA 650-...
DoorCom Analog
1–31 (address dependent)
DCIP 650-...
DoorCom IP
1–31 (address dependent)
The components can be linked
to form a system both over a
single-line system and a multiple-line system. The difference
between the systems lies in the
upgrade capability and the performance scope of the lines:
• Single line systems are
restricted to 31 users.
• Multiple line systems can
accommodate up to 15 lines
with 31 users each, i.e. up to
465 users. In additional, if programmed accordingly internal
calls are also possible within
one line.
For more information, see the
following page.
User
The terms „user“ and „component“ or „device“ do not mean
the same thing. Depending on
its function, a component uses
a certain bandwidth within the
bus system can therefore count
as 0, 1 or 2 users. The upgrade
capability of the lines always
refers to the number of users
and not to the number of connected components or devices.
Interface to the IP network
5
Siedle In-Home bus
General
Structure of the conductor
network
The Siedle In-Home bus can be
structured as a single line or a
multiple line system. The installation can be looped through
from device to device or structured via a side circuit with bus
distributor. Mixed structures are
also possible.
Single line system
Systems with up to 31 users
with one speech channel.
The basic functions calling,
speech, door release and light
switching to the front door
are performed as a matter of
course, with several doors.
In addition, there are a many
different performance features
available.
Several speech channels or a
higher number of users call for
a multiple line system.
Parallel call
A call button can be assigned
to several bus telephones in
parallel. If the call button is
pressed, these ring at the same
time. The bus telephone which
is picked up first or at which
the speech button is pressed
first is connected to the caller.
Internal speech operation
The users can intercommunicate internally provided the
devices have been programmed
accordingly.
The storey door loudspeaker
can be installed instead of a
storey call button. All that is
required in addition is a
12 V AC supply for the door
release.
Interface to the telephone
network
Instead of a user, an analogue
interface can be connected to
link up to the telephone network. The DoorCom Analog
DCA 650-... can be used to
create this link.
Interface to IP technology
The DoorCom IP links the
Siedle door station to a TCP/
IP network/Intranet. As a functional unit, the DCIP 650-...
consists of the devices system
interface In-Home bus
SII 650-..., system interface
video server SIVS 610-... and
IP video server IPVS 600-...
Switching and control
elements for greater
convenience
In the central subdistributor or
at any optional location in the
line, bus switching modules
BSE 650-..., BEM 650-... and
BSM 650-... can be installed
and actuated by the authorized
users,
e.g. for staircase lighting in
addition to the external lighting
or all-round lighting.
At any optional position of the
In-Home bus, switching and
control elements BSM/BSE/
BEM 650-... can be installed for
selective actuation of individual
or several users.
(e.g. for roller blind actuation)
Status display for important
information
At the deluxe devices BTC/BFC/
BTCV/BFCV 850-..., status messages can be displayed which
are transmitted by a bus input
module BEM 650-... or by a
switching module BSE 650-... .
(e.g. garage door open, terrace
door open or fault in the air
conditioning unit)
Programming is described in
the system manual enclosed
with the BNG/BVNG 650-... ,
and can be performed manually, using Plug+Play or via a
PC.
Plug+Play programming refers
exclusively to the assignment of
bus telephones to call buttons.
For programming with the PC,
the interface PRI 602-... USB
with software BPS 650-... from
V 2.00 is required.
When programming using the
PC, access rights to status displays or control functions are
defined for the individual users.
Multiple line system
In contrast to the single line
system, in multiple line systems
installations can be formed
encompassing up to 465 users.
At first glance, the only difference in the performance
features available appears to be
the maximum number of users.
However, a significant difference exists in terms of the
number of speech channels.
One speech channel is available
per line.
In multiple line systems, it is
possible for a bus telephone
to communicate e.g. with the
door station and at the same
time bus telephones on a different line to communicate
internally via another speech
circuit.
In single line systems, only one
speech channel is ever possible.
Several speech channels
Internal units connected to
one line can speak internally. If
the system is configured with
several lines, in each line a call
can be held without mutual
interference.
No internal calls are possible
across different lines.
There is only ever one speech
channel available to the shared
entrance door, even if several
doors are completely or partially shared.
An example of a multiple line
system:
A project accommodates several independent bureaus or
practices.
The entrances are jointly used
and internal communication is
also required.
Procedure during
planning
Even extensive and complex
Siedle In-Home bus systems
are simple to plan. In drawing
up the planning documentation, we have used a systematic approach which applies
throughout the entire planning
process.
We consider the most logical
procedure is to start with
planning the door area then
to work on the living area and
to finish with the distribution.
Distribution encompasses not
only the power supply to the
devices but also any switching
and control functions.
In each area, i.e. door, living
area and distribution, first the
audio and then the video components are described.
In the Siedle In-Home bus, the
audio, video and control signals
are transmitted via two cores
routed side by side.
General
The design of the door area
can differ considerably. For
standard applications, the door
area design is simple to put
together using the Siedle purchase order catalogue.
The planning documents refer
exclusively to the electrical
components required to ensure
that the system functions reliably.
Additional functions and design
elements have to be taken into
consideration during planning
and subsequently at the installation stage.
When planning the door station, pay attention to the
mounting height, in particular
when a video camera is being
used.
Recommended mounting
height appr. 1.60 m to centre
camera
Door area
The door area offers wide
scope for creative design.
The door station can be
equipped, for instance, with:
• Siedle Vario,
• Siedle Classic,
• Siedle Select door station,
• Siedle Steel or
• Siedle custom-fit door loudspeaker for mounting in an
existing intercom compartment.
7
Siedle In-Home bus: Audio
Ranges and system limits
Single line system
• Max. 50 m between the
bus telephone and storey call
button ERT
• Max. 300 m from the bus
line rectifier to the most distant
door station
• Max. 300 m from the bus line
rectifier to the most distant bus
telephone
• Total laid conductor network
length max. 1500 m
max. 50 m
2
2
ERT
2
BTC 850-...
2
2
ERT
2
max. 50 m
max. 300 m
In single line systems
• The range
• Max. 31 users
• 1 speech channel
BTS 850-...
BFS 850-...
2
ERT
2
BFC 850-...
2
2
BNG 650-...
max. 300 m
All specifications relating to
ranges and functional characteristics refer to the above
mentioned conductor material
with 0.8 mm core diameter.
With a core diameter of
0.6 mm, the range is halved.
The system limits in the conductor network are also halved.
When converting old bell
systems (1+n installation):
If two continuous cores are not
available, all n cores must be
connected to each other and
used as one bus core.
This reduces the possible length
of the total laid conductor network to max. 400 m per line.
4
Door station
2
Tö
ERT
max. 50 m
max. 50 m
BTS 850-...
BFC 850-...
ERT
2
2
BTC 850-...
BFS 850-...
ERT
2
2
ERT
2
BFC 850-...
max. 300 m
BTC 850-...
ERT
2
2
2
BTS 850-...
BFS 850-...
ERT
2
ERT
2
2
2
4
Door station
2
Tö
BNG 650-...
max. 300 m
BNG 650-...
max. 300 m
ERT
2
2
In multiple line systems
• The range
• Max. 15 lines
• Max. 15 speech channels
• Max. 31 users per line
• Max. 465 users at
max. 15 lines.
ERT
2
2
max. 300 m
Multiple line system
• In multiple line systems,
several single line systems are
linked from BNG 650-... to
BNG 650-...
• Up to 15 lines possible
• A maximum of 300 m
between the most distant bus
line rectifiers
• Distance from the
BNG 650-... to the most distant
user max. 300 m
• Max. 50 m between the bus
telephone BTS/BFS/BTC/BFC
and storey call button ERT
• Total laid conductor material
length within one line max.
1500 m
• Maximum configuration
465 users at max. 15 lines.
4
Door station
2
Tö
9
Siedle In-Home bus: Audio
Single line system up to max. 31 users
Cable size diagram
ГњV-THa-1/1
Speech connection to the door
station via the BTS/BFS/BTC/
BFC 850-... in a single or
multiple family home.
In conjunction with the BTS/
BFS/BTC/BFC 850-... also for
internal telephony and/or for
control functions in sophisticated single or multiple family
homes where an advanced
level of convenience is required.
Independently of the device,
whether bus telephone BTS/
BTC 850-... with receiver or
BFS/BFC 850-... as handsfree
bus telephone, each system
can be individually planned and
constructed.
The BTS/BFS/BTC/BFC can be
installed and operated in combination in a single system.
Where the execution of other
control functions is required
alongside door release and
light using the BTC/
BFC 850-... , the bus switching
module BSM 650-... or bus
switching unit BSE 650-... is
required in addition.
See switching/control functions
page 22 and 34.
Functional characteristics
Call, speech, door release and
light operation between the
door station and the connected
BTS/BFS/BTC/BFCВ 850-... units.
Internal speech communication from bus telephone to bus
telephone is possible within
one line.
Third party audio privacy function.
11 different electronic call signals freely selectable including
chime.
Call differentiation between
door calls, storey calls and
internal calls is freely selectable.
Call silencing with status display and optical call display
integrated.
Door release actuation at the
door station which placed the
last call and light actuation are
possible at any time.
BTS 850-...
2
ERT
2
2
2
ERT
2
BTC 850-...
BTC 850-...
2
2
2
2
2
ERT
2
ERT
BTC 850-...
BTC 850-...
2
ERT
2
BTS 850-...
BTS 850-...
2
ERT
2
BNG 650-...
BNG 650-...
4
Key
ERT = Storey call button
Tö = Door release
(12 V AC min. 20 Ohm)
ERT
2
2
Door station
ERT
2
2
Door release actuation time:
Fixed at 3 secs.
Light contact actuation time:
0.4 secs with BPS 650-... , can
be changed from V 2.00
ERT: Storey call button
Installation can be
performed from one device
to the next or via storey
distributors. Mixed installation is also possible.
BTS 850-...
2
2
Tö
4
Door station
2
Tö
4
Door station
2
Tö
Siedle In-Home bus: Audio
Multiple line system up to max. 465 users
Cable size diagram
ГњV-THa-n/n
Speech connection to the door
station via the BTS/BFS/BTC/
BFC 850-... in residential complexes.
In conjunction with the BTS/
BFS/BTC/BFC 850-... additional
control functions and also
internal telephony within one
and the same line are possible.
Independently of the device,
whether bus telephone BTS/
BTC 850-... with receiver or
BFS/BFC 850-... as handsfree
bus telephone, each system
can be individually planned and
constructed.
The BTS/BTC/BFS/BFC 850-...
can be installed and operated
in combination in a single
system.
Where the execution of other
control functions is required
alongside door release and
light using the BTC/
BFC 850-... , the bus switching
module BSM 650-... or bus
switching unit BSE 650-... is
required in addition.
See switching/control functions
page 22 and 34.
Functional characteristics
Call, speech, door release and
light operation between the
door station and the connected
BTS/BFS/BTC/BFCВ 850-... units.
Internal speech communication from bus telephone to bus
telephone is possible within
one line.
Third party audio privacy
function.
11 different electronic call signals freely selectable including
chime.
Call differentiation between
door calls, storey calls and
internal calls is freely selectable.
Call silencing with status display and optical call display
integrated.
Door release actuation at the
door station which placed the
last call and light actuation are
possible at any time.
Door release actuation time:
Fixed at 3 secs.
Light contact actuation time:
0.4 secs with BPS 650-... , can
be changed from V 2.00
ERT: Storey call button
Installation can be
performed from one device
to the next or via storey
distributors. Mixed installation is also possible.
Multiple line system
• A BNG 650-... is required
for every line
• In multiple line systems,
1 x bus supply unit accessory
ZBVG 650-... is always required.
• One speech channel is available per line.
BTS 850-...
BTS 850-...
2
2
2
ERT
BTC 850-...
2
2
BTC 850-...
BTC 850-...
2
2
2
ERT
BTC 850-...
BTC 850-...
2
2
2
ERT
ERT
2
BNG 650-...
5
Door station Tö
2
2
2
2
ERT
BTC 850-...
2
2
2
ERT
BTC 850-...
2
ERT
2
2
2
2
2
ERT
BTC 850-...
2
ERT
2
2
2
2
2
ERT
2
ERT
BTC 850-...
2
BFC 850-...
2
2
2
2
2
ERT
2
BNG 650-...
ZBVG 650-...
BNG 650-...
5
2
Door station Tö
Key
ERT = Storey call button
Tö = Door release
(12 V AC min. 20 Ohm)
11
Installation notes
BTS 850-...
BTS 850-...
2
2
2
2
ERT
BTC 850-...
2
2
BTC 850-...
2
2
2
BTC 850-...
2
2
2
5
Door station
2
Tö
The devices BTS/BTC 850-... can be
operated in combination in any optional
form with BFS/BFC 850-... in a single
system.
2
ERT
BFS 850-...
2
2
2
ERT
2
BNG 650-...
2
2
2
2
ERT
2
ERT
BFC 850-...
ERT
BFC 850-...
2
2
2
2
2
ERT
2
ERT
BFS 850-...
2
ERT
2
2
2
2
ERT
BTC 850-...
2
ERT
BFS 850-...
2
BFC 850-...
2
2
ERT
2
BNG 650-...
ZBVG 650-...
BNG 650-...
5
Door station
2
Tö
Conductor routing
In order to comply with the
general safety regulations for
telecommunication systems in
accordance with VDE 0100 and
VDE 0800, and to prevent electrical interference, ensure separate routing of heavy and light
current conductors. A distance
of 10 cm must be adhered to.
Conductor material
YR
Light current cable
J-Y(ST)Y Twisted pair
conductors,
shielded
A2Y(ST)2Y Buried
telecommunication
cable
For new installations,we recommend using standard available
conductor material J-Y(ST)Y
with 0.8 mm core diameter.
The Siedle In-Home-bus must
be installed on two YR cores
positioned side by side, and
when using J-Y(ST)Y on one
pair of cores.
Using J-Y(ST)Y conductors
reduces the likelihood of interference.
Siedle In-Home bus: Video
Ranges and system limits
BFCV 850-...
max. 50 m
BFCV 850-...
max. 50 m
ERT
ERT
ERT
BFSV 850-...
UAE 8 (8)
BVVU 650-...
max. 100 m
ERT
max. 100 m
In-Home bus components
without video
In systems with audio/video
devices, the range for all users
is determined by the specifications for In-Home bus: Video.
The audio users have no influence over the attenuation
values.
Connection to In-Home bus:
Video via bus audio decoupler
BAA 650-...
The attenuation/range calculation is described from page 16.
Our training and exhibition
centres will be pleased to
advise you.
BTCV 850-...
BTCV 850-...
S 850-...
ERT
ERT
BTSV 850-...
BTSV 850-...
ERT
ERT
BVNG 650-...
TR 603-...
Key
ERT = Storey call button
Tö = Door release
(12 V AC min. 20 Ohm)
BVNG 650-...
TR 603-...
BVVS 650-...
max. 100 m
max. 100 m
The Siedle In-Home bus: Video
is a high-performance communication system with a wide
range of performance features
which is simple to set up.
The basic functions calling,
speech, door release, light,
switching and control functions
are supplemented by video.
Installation in the building can
be performed from bus telephone to bus telephone or via
the side circuit with bus distributor. Mixed structures are also
possible. In systems with several indoor units, the S 850-…
units are always connected via
a bus distributor BVVU 650-… .
In the case of systems which
are looped through and
which have fewer than three
entrances with camera, an
attenuation calculation in the
single line system up to 100 m
is not necessary. The specification 100 m refers to the
distance from the bus video
line rectifier to the most distant
user.
In systems with side circuit
installation and bus distributor,
a conductor length exceeding
100 metres, more than 2
entrances with camera and
more than 10 video indoor
units, an attenuation or range
calculation must be performed.
Door station
Tö
Door station
Tö
Door station
Tö
13
Siedle In-Home bus: Video
Single line system up to max. 31 users
Cable size diagram
ГњV-THa-1/1
Speech and video link to the
video door station via bus
telephones BTSV/BFSV/BTCV/
BFCV 850-..., S 850-... .
In conjunction with the video
indoor units also for internal
telephony for one and twofamily homes and/or for control
functions where an advanced
level of convenience is required.
Where the execution of other
control functions is required
alongside door release and
control functions using the
BTSV/BFSV/BTCV/BFCV 850-... ,
the bus switching module/unit
BSM/BSE 650-... is required in
addition.
See switching/control functions
page 22 and 34
Functional characteristics
Call, speech and video link via
the Video door station. Door
release and light control from
the connected BTSV/BFSV/
BTCV/BFCVВ 850-..., S 850-...
are possible at any time.
Internal speech communication from bus telephone to bus
telephone is possible within
one line.
Third party audio privacy function.
11 different electronic call
tones to chose from. Call differentiation between door
calls and storey calls is freely
selectable.
Call silencing with status display and optical call display
integrated.
Door release actuation at the
door loudspeaker which placed
the last call and light actuation
are possible at any time.
2
ERT
ERT
2
2
2
UAE 8 (8)
BFSV 850-...
ERT
2
BFCV 850-...
2
BVVU 650-...
2
2
BVVU 650-...
ERT
2
2
2
BTCV 850-...
BTCV 850-...
S 850-...
2
BFSV 850-...
ERT
2
BTSV 850-...
BTSV 850-...
ERT
ERT
2
2
2
BVNG 650-...
TR 603-...
4
Door station
ERT
2
2
2
Key
ERT = Storey call button
Tö = Door release
(12 V AC min. 20 Ohm)
BVVU 650-...
BVVU 650-...
Door release actuation time:
Fixed at 3 secs.
Light contact actuation time:
0.4 secs with BPS 650-... , can
be changed from V 2.00
ERT: Storey call button
Installation can be
performed from one device
to the next or via storey
distributors. Mixed installation is also possible.
2
2
Tö
BVNG 650-...
TR 603-..
BVVS 650-...
5
Door station
1
Tö
5
Door station
1
Tö
Siedle In-Home bus: Video
Multiple line system up to max. 465 users
Cable size diagram
ГњV-TVHa-n/n
Speech and video link to the
video door station via bus
telephones BTSV/BFSV/BTCV/
BFCV 850-..., S 850-... .
In conjunction with the video
indoor units additional control
functions and also internal
telephony within one and the
same line are possible.
Multiple line system
• Max. 15 lines possible
• Max. 15 speech channels
possible
• Max. 31 users per line
• Each line requires its own
BVNG 650-... with
ZBVNG 650-...
• One bus supply unit accessory ZBVG 650-... is required
per system
Where the execution of other
control functions is required
alongside door release and
control functions using the
BTSV/BFSV/BTCV/BFCV 850-... ,
the bus switching module/unit
BSM/BSE 650-... is required in
addition.
See switching/control functions
page 22 and 34
Functional characteristics
Call, speech and video link via
the Video door station. Door
release and light control from
the connected BTSV/BFSV/
BTCV/BFCVВ 850-..., S 850-...
are possible at any time.
Internal speech communication from bus telephone to bus
telephone is possible within
one line.
Third party audio privacy function.
11 different electronic call
tones to chose from. Call differentiation between door
calls and storey calls is freely
selectable.
Call silencing with status display and optical call display
integrated.
Door release actuation at the
door loudspeaker which placed
the last call and light actuation
are possible at any time.
BFCV 850-...
BTSV 850-...
2
2 ERT
BVVU 650-...
2 ERT
ERT
2
2
2 ERT
2
2 ERT
BTCV 850-...
2 ERT
2 ERT
2
2 ERT
BTSV 850-...
2 ERT
2
2 ERT
2 ERT
2
5
2 ERT
2
BVVU 650-...
2
2
BVNG 650-...
ZBVNG 650-...
TR 603-...
BVVS 650-...
1
2
2
BVVU 650-...
2
BVNG 650-...
ZBVNG 650-...
TR 603-...
ZBVG 650-...
BVVU 650-...
BFSV 850-...
2
BVVU 650-...
2
2
BVVU 650-...
BTCV 850-...
2
BVVU 650-...
BFCV 850-...
2
2
2
2
BVVU 650-...
BFSV 850-...
S 850-...
2
BVVU 650-...
BTSV 850-...
2
2
Door release actuation time:
Fixed at 3 secs.
Light contact actuation time:
0.4 secs with BPS 650-... , can
be changed from V 2.00
ERT: Storey call button
2
BVVU 650-...
BFCV 850-...
2
BVVU 650-...
BTCV 850-...
2
BVNG 650-...
ZBVNG 650-...
TR 603-...
5
1
Installation can be
performed from one device
to the next or via storey
distributors. Mixed installation is also possible.
Key
ERT = Storey call button
Tö = Door release
(12 V AC min. 20 Ohm)
Door station
Tö
Door station
Tö
15
Installation notes
Conductor routing
In order to comply with the
general safety regulations for
telecommunication systems in
accordance with VDE 0100 and
VDE 0800, and to prevent electrical interference, ensure separate routing of heavy and light
current conductors. A distance
of 10 cm must be adhered to.
The conductor from the door
loudspeaker must be laid
directly without branching
from the main junction box,
or where applicable can also
be looped via other door loudspeakers.
Range
Siedle In-Home bus:
Video
Conductor material
YR
Light current cable
J-Y(ST)Y
Twisted pair
conductors,
shielded
A2Y(ST)2Y Buried
telecommunication
cable
For new installations,we recommend using standard available
conductor material J-Y(ST)Y
with 0.8 mm core diameter.
The Siedle In-Home-bus must
be installed on two YR cores
positioned side by side, and
when using J-Y(ST)Y on one pair
of cores.
Using J-Y(ST)Y conductors
reduces the likelihood of
interference.
All specifications relating to
ranges and functional characteristics refer to the above
mentioned conductor material
with 0.8 mm core diameter.
With a core diameter of
0.6 mm, the range is halved.
The ranges in the conductor
network are halved.
Single line system
• Max. 50 m between BTSV/
BFSV/BTCV/BFCV 850-...,
S 850-... and storey call button
ERT
• Distance from the
BVNG 650-... to the most
distant user max. 100 m with
YR 0.8 mm, max. 150 m with
J-Y(ST)Y 0.8 mm core diameter
• Total laid conductor network
length max. 1500 m
Multiple line system
• Max. 50 m between the
bus telephone and storey call
button ERT
• Distance from the
BVNG 650-... to the most
distant user max. 100 m with
YR 0.8 mm, max. 150 m with
J-Y(ST)Y 0.8 mm core diameter
• Total laid conductor material
length within one line max.
1500 m
• Maximum of 100 m between
the most distant bus video line
rectifiers, YR cable with
0,8 mm diameter, max. 150 m
with J-Y(ST)Y 0.8 mm core
diameter
• Total laid conductor network
admissible connecting all
BVNG 650-... units max. 750 m
with YR 0.8 mm, max. 1125 m
with J-Y(ST)Y 0.8 mm core
diameter.
Attenuation values
Siedle In-Home bus:
Video
System limits
The damping value in dB is only
significant for those areas or
lines in which video components are mounted.
In the case of systems which
are looped through and
which have fewer than three
entrances with camera, an
attenuation calculation in the
single line system up to 100 m
is not necessary.
In single line systems
• The range
• Max. 31 users
• 1 speech channel
In systems with side circuit
installation via bus distributor,
a conductor length exceeding
100 metres, more than 2
entrances with camera and
more than 10 bus telephones
with colour monitor, an attenuation or range calculation must
be performed.
For complex systems and large
ranges/attenuation, the attenuation /range calculation is
described over the next pages.
Our training and exhibition
centres will be pleased to
advise you.
See page 39
In multiple line systems
• The range
• Max. 15 lines
• Max. 15 speech channels
• Max. 31 users per line
• Max. 465 users at max. 15
lines.
Siedle In-Home bus: Video
Range
With In-Home bus: Video, a
distinction is made between
a camera branch (in which
the door stations with video
are grouped) and a monitor
branch (in which the bus telephones with colour monitor
are grouped).
Attenuation must not exceed
45 dB at any point of the
overall system, i.e. a maximum
of 45 dB is admissible from the
camera branch to the most
distant user. If this value is
exceeded in a branch/line, the
ZBVNG 650-... is available to
compensate for the loss.
This is plugged into the
BVNG 650-... .
In the monitor branch, attenuation of max. 55 dB is then
admissible.
In the camera branch, attenuation of max. 45 dB is then
admissible.
Range calculation
L Line
Total laid conductor material within a line
1500 m
camera branch
Maximum distance between BVNG 650-...
and the most distant user in the
camera branch
150 m = 30 dB
100 m = 20 dB
monitor branch
L BVNG
conductor material
with J-Y(St)Y
with YR
A total 1
conductor material
with J-Y(St)Y
with YR
Maximum distance from a BVNG 650-... to
the most distant BVNG 650-...
150 m = 30 dB
100 m = 20 dB
with J-Y(St)Y
with YR
Operating mode switch 1-standard-2
1
Operation in existing systems with BTS/BTC 750-...,
replaces BVSG 650-... max. 100m
NORM
Normal operation in a new system with
the devices BTSV/BFSV/BTCV/BFCV 850-...
max. 150 m
max. 100 m
Total attenuation between the most
distant camera door loudspeaker and
the most distant apartment station of
a line
45 dB
A total 2
Maximum distance between BVNG 650-...
and the most distant user in the
monitor branch
150 m = 30 dB
100 m = 20 dB
2
Operating mode switch
The operating mode switch at
the BVNG 650-... is used to
define how the system is operated.
Attenuation values
Total attenuation between the most
distant camera door loudspeaker and
the most distant apartment station of
a line, if the relevant BVNG 650-...
encompasses a ZBVNG 650-...
45 dB + 55 dB
Attenuation camera branch
max. 45 dB
Attenuation monitor branch
max. 55 dB (with ZBVNG 650-...)
Attenuation of 2 dB is assumed
for every 10 m of conductor
length.
with J-Y(St)Y
with YR
Increased range in new systems with the devices
BTSV/BFSV/BTCV/BFCV 850-... max. 200m only with
J-Y(ST)Y (with supplementary installation)
17
Siedle In-Home bus: Video
Range
Monitor branch
The monitor branch is defined
as the area in which no door
stations with video are connected.
Loop-through connection
In the monitor branch, looping
through is possible from bus
telephone to bus telephone.
If you wish users without
video to be connected, a bus
audio decoupler BAA 650-...is
required.
Other audio or control components are then also subsequently looped through in the
same way.
Camera branch
with J-Y(St)Y
Monitora branch
max. 150 m
max. 100 m
max. 150 m
max. 100 m
with YR
BVVU 650-...
BVVU 650-...
BVVU 650-...
TR, BVNG,
ZBVNG 650-...
Entrance x
Entrance 2
BCMC 650-...
BTLM 650-...
BTM 650-...
BVVU 650-...
max. 45 db
with ZBVNG
max. 55 dB
max. 45 dB
Monitor branch
Camera branch
TR, BVNG,
ZBVNG, ZBVG 650-...
BVVU 650-...
BTSV 850-...
BVNG 650-...
ZBVNG 650-...
BVVU 650-...
BVVU 650-...
BVVU 650-...
BTSV 850-...
BFSV 850-...
BVVU 650-...
BFCV 850-...
BVVU 650-...
S 850-...
BTSV 850-...
without ZBVNG
max. 45 dB
Camera branch
The camera branch is defined
as the area in which the door
stations with video are connected. Door stations without
video can be connected via the
BAA 650-... .
BVVU 650-...
BTCV 850-...
BVVU 650-...
BFCV 850-...
BVNG 650-...
ZBVNG 650-...
BVVU 650-...
max. 55 dB
BVVU 650-...
BFCV 850-...
Attenuation values
Camera branch
Monitor branch
Basic circuit
Basic circuit
BAA 650-...
BAA 650-...
Distribution
BVVS 650-...
BVVS 650-...
BVVU
BVVU
BVVU
BVVU
BVVU
BVVS
BVVS
BVVU 650-...
• When looping through from
bus telephone to bus telephone
in the monitor branch, only
the conductor attenuation is
taken into consideration in the
attenuation calculation.
• When calculating the conductor networks with side
circuit installation and bus
distributor, the distributor components BVVU/BVVS 650-...
must not be left out of consideration.
• Unconnected looping terminals in the components
BVVU 650-... and BAA 650-...
must always be terminated
with an RC element in order to
prevent disturbance to the bus.
Use the required RC element
from already installed devices
BTSV/BFSV/BTCV/BFCV 850-...
or BVVU 650-... !
Camera branch
Monitor branch
No bus distributor is required
with a video door station.
No bus distributor is required
if it is possible to loop through
from BTSV/BFSV/BTCV/BFCV
to BTSV/BFSV/BTCV/BFCV. The
integrated distributor in the bus
telephone with monitor uses
attenuation = 0 dB.
with BAA 650-...
Connection of audio users
(e.g. BTLM 650-... or
BTLE 050-...) or users for
switching and control
functions.
Attenuation = 0 dB
with BVVS 650-...
More than one video door
station in the camera branch
with “star shaped” conductor
routing.
Attenuation = 3 dB
with BVVU 650-...
More than one video door station in the camera branch with
“looped through” conductor
routing.
Throughput attenuation = 1 dB
Input attenuation = 12 dB
with BAA 650-...
Connection of audio users
(BTS/BFS/BTC/BFC 850-...,
DCA 650-...) or users for
switching and control functions.
with BVVS 650-...
Within the In-Home bus: Video
more than one side circuit is
required. Attenuation = 3 dB
* At the outputs of a
BVVS 650-..., additional
distribution is required via
BVVU 650-... . Audio users are
connected via BAA 650-... .
with BVVU 650-...
Connection of a bus telephone
with monitor to a side circuit
with “looped through”
conductor routing.
Throughput attenuation = 1 dB
Output attenuation = 12 dB
BVVU 650-...
19
Example for calculating attenuation
BVVU 650-...
Example:
The BVVUs in the camera
branch are assigned directly to
the subdistributor.
L=5m
12 dB
BTSV 850-...
L = 12 m
Camera branch
The most distant user (door 2)
in the camera branch
L = 65 m = 13 dB plus the
attenuation of the two following symmetrical bus video
distributor
2 x BVVS = 6 dB
Attenuation in the camera
branch = 19 dB
L = 15 m
BVVU 650-...
1 dB
BVVU 650-...
12 dB
12 dB
BTCV 850-...
L = 12 m
L=4m
L = 16 m
BVVS 650-...
3 dB
BAA 650-...
0 dB
Apartment 6
BFSV 850-...
BVVU 650-...
1 dB
3 dB
BTS 850-...
12 dB
L=9m
L=4m
L=8m
12 dB
L=7m
L=6m
12 dB
L=3m
L=6m
12 dB
L = 12 m
L=5m
Distribution
Apartment 1
BFS 850-...
BAA 650-...
0 dB
Apartment 2
BTSV 850-...
Apartment 3
BTCV 850-...
Apartment 4
BFCV 850-...
Apartment 5
BFSV 850-...
L=5m
Distribution
L = 25 m
Siedle Vario
3 dB
L = Conductor length
BVVS 650-...
3 dB
Example:
In the camera branch
Conductor length 25 m = 5 dB
In the monitor branch
Conductor length 26 m
= 5.2 dB
The throughput attenuation
(BVVU) 1 dB and the output
attenuation (BVVU)
12 dB must be added to this.
5 dB + 5.2 dB + 1 dB + 12 dB
= 23.2 dB
3 dB
BVVS 650-...
3 dB
L=6m
Siedle Vario
Door 1
L = 65 m
Siedle Vario
Door 2
L = 35 m
Siedle Vario
Door 3
L = Conductor length
Monitor branch
UV to the most distant residential unit apartment 5
L = 57 m = 11.4 dB plus the
output attenuation of
1 x (BVVS) 3 dB
plus 3 x throughput attenuation (BVVU) = 3 dB
plus 1 x output attenuation
(BVVU) 12 dB
Attenuation in the monitor
branch=
11.4 dB + 3 dB + 3 dB + 12 dB
= 29,4 dB
Total attenuation = Camera
branch + monitor branch
19 dB + 29.4 dB = 48.4 dB
In the BVNG 650-... a ZBVNG
is required as the attenuation
between the door loudspeaker
and most distant residential
unit amounts to more than
45 dB.
Storey door station at the
In-Home bus: Video
Storey door station at the
In-Home bus: Audio
Additional information and
supply components are
required.
Independently of whether a
single or multiple line installation system is used, a storey
door station with video can be
connected instead of a storey
call button.
BFS 850-...
Independently of whether a
single or multiple line installation system is used, a storey
door station with video can be
connected instead of a storey
call button.
If there is a ZBVNG 650-... integrated in the BVNG 650-..., the
BTSV 850-...
2
2
ERT
Installation from the storey
door station to the central
distributor must be performed
using a separate conductor.
Door station *
2
* The power supply is provided
by additional installation and
supply components.
** When using a central
supply, additional cores are
required.
installation must be performed
using a central distributor at
the camera branch.
BFSV 850-...
2
2
BTSV 850-...
2
BVVU 650-...
2
2
Key
ERT = Storey call button
Tö = Door release
(12 V AC min. 20 Ohm)
ERT
2
BVVU 650-...
2
ERT
2
BVVU 650-...
2
Tö
2
Door station *
BFCV 850-...
BTCV 850-...
BTC 850-...
2
2
BVVU 650-...
BTCV 850-...
2
BVVU 650-...
BVVU 650-...
2
2
2
2
ERT
2
ERT
2
ERT
2
2
BAA 650-...
2
2
2
BFSV 850-...
BTSV 850-...
BTC 850-...
ERT
2** Tö
2
BVVU 650-...
BVVU 650-...
2
2
BVVU 650-...
ERT
ERT
2
2
ERT
2
ERT
2
2**
2
2
2
2
2
2
2
Stories
Door station
2
ERT
2
S 850-...
2
BVVU 650-...
BTS 850-...
TR 603-...
BFCV 850-...
BFCV 850-...
BTCV 850-...
ERT
2
2
2
ERT
BVVU 650-...
2
2
Tö
BNG 650-...
4
Door station
2
Tö
BVNG 650-...
ZBVNG 650-...
TR 603-...
BVVS 650-...
BVNG 650-...
ZBVNG 650-...
TR 603-...
BVVS 650-...
5
Door station Tö
1
BVNG 650-...
ZBVNG 650-...
TR 603-...
ZBVG 650-...
1
5
Door station
Tö
21
Switching and control functions
at the Siedle In-Home bus
Using the switching and control components, functions
can be performed or messages
received at any optional point
in the Siedle In-Home bus.
Messages via the bus input
module BEM 650-... can
also initiate functions on the
In-Home bus.
For example a BTC/BFC 850-...
can actuate a BSE 650-... and
simultaneously receives a status
feedback. At the In-Home bus:
Video the switching and control components and devices
without video must be decoupled.
Other devices are then looped
through.
BTSV 850-...
ERT
2
2
BTCV 850-...
ERT
2
BEM 650-...
BAA 650-...
2
ERT
2
2
UAE 8 (8)
2
BVVU 650-...
2
BFCV 850-...
S 850-...
2
ERT
2
BSE 650-...
BEM 650-...
2
2
BAA 650-...
BVNG 650-...
4
Door station
2
Tö
BSE 650-0
Bus switching unit with bistable
relay, suitable for mounting in a
55 junction box.
Actuation possible via BEM,
using the programmable buttons of the system users or in
parallel to a door call button.
Power supply via the In-Home
bus
Contact type: Changeover
switch max. 250 V AC, 6 A
Switching time: adjustable from
0.4 secs. to 19 mins. 59В secs. /
switching on and off
Protection system: IP 20
Ambient temperature:
0В°C to +40В°C
Dimensions (mm) dia. x H:
51 x 23
BSM 650-02
Bus switching module in switch
panel housing with 4 integrated relays, each with one
potential-free work contact.
Programmed functions can be
actuated using the programmable buttons of the system
users or in parallel to a door
call button to actuate an
external signalling device.
Operating voltage: 12 V AC
Operating current:
max. 240В mA
Contact type: 4 n.o. contacts,
max. 24 V, 2 A
Switching time: Adjustable
from 1 to 10 sec.
Horizontal pitch (HP): 3
Dimensions (mm) W x H x D:
53.5 x 89 x 60
BEM 650-0
Bus input module for mounting
in a 55 junction box with an
input for tripping switching
functions/transmitting messages at the In-Home bus.
Activation possible via potential-free contact or 4 - 30 V DC,
10 mA.
Power supply via the In-Home
bus
Protection system: IP 20
Ambient temperature:
0В°C to +40В°C
Dimensions (mm) dia. x H:
51 x 23
Siedle In-Home bus
combined with
Vario bus
Ranges in the Vario bus
The modules COM/ELM or
FPM 611-... are used to actuate
control functions which are
evaluated and implemented
the evaluating unit EC 602-... .
The control functions are then
executed via the In-Home bus.
Control functions directly from
the In-Home bus and from the
Vario bus can be combined.
The range depends on the type
of installation, the core diameter and the connected load
values „AW“ of the connected
devices.
In order to utilize Vario bus
control functions, an additional
conductor with 4 cores is
required from the input module
to the EC 602-... .
Input module at the
Vario bus
ELM/COM max. 250 m
ELM 611-...
TR 603-...
Range between the transformer and input modules
with star-shaped installation
Max. 250 m using 0.8 mm core
diameter and with connected
load value „AW“ 1.
A second connected load
value in the same line halves
the range.
Connected load values AW
COM 611-..., DRM 611-...,
ELM 611-..., EC 602-... = AW 1
FPM 611-..., EC 602-... with
ECE 602-... or RC with
RCE 602-... = AW 2
One TR 603-... supplies 2
AWs
COM 611-...
4
EC 602-...
ECE 602-...
FPM 611-...
FPM max. 130 m
COM 611-01
Code lock module as an input
unit for the placement of codes
for control functions in conjunction with the Siedle Vario
bus.
ELM 611-01
Electronic key read module as
a no-contact control system
in conjunction with the Siedle
Easikey controller EC 602-...
Reading unit for electronic keys
or cards for actuation of functions at the Vario bus.
The conductor network
laid throughout the entire
Vario bus must not exceed
2000 m.
FPM 611-01
Fingerprint module as a monitoring system with function
LEDs. For actuation of functions
in conjunction with Easikey
controller EC 602-... at the
Vario bus.
23
Device description
Vario door station
COM/DRM 611-... as
call module
BTS 850-...
2
2
ERT
BFC 850-...
BTLM 650-04
Bus door loudspeaker module
in 611 Vario design in conjunction with the Siedle In-Home
bus.
With front louvre made of
weather- and UV-proof
polycarbonate, tropicalized
loudspeaker, long-life electret microphone and volume
controller for loudspeaker.
Illuminated low current light
button. Integrated video control and working contact for
the door release. DR contact
can be controlled via the bus
line without supplementary
wiring. Acoustic feedback
when pressing one of the call
buttons at the BTM 650-01 to
-04.
Up to max. 40 call button
modules can be connected
in any optional combination,
allowing up to max. 160 users.
1 BTLM 650-04 corresponds to
2 system users.
BTM 650-...
Bus call button modules
BTM 650-... with 1, 2, 3 or 4
call buttons. The BTM 650-... is
connected to the BTLM 650-...
via ribbon cable.
door release
Siedle door release units are
high-resistance > 20 Ohm and
provide operating reliability
even over long ranges.
Standard commercially available door release units
8 – 12 V AC, 20 Ohm can be
connected.
COM 611-02
Code lock module as an input
unit for the placement of door
calls and control functions in
conjunction with the Siedle
Vario bus.
• With keyboard, for calling in
conjunction with the bus interface module BIM 650-...,
• For controlling in conjunction
with the Easikey controller
EC 602-...
• C button for cancelling incorrect inputs
• TÖ button for direct door
release via the EC 602-....
In order to use the control
functions or the door call
facility, 4 additional cores are
required from the input module
to the EC 602-... or
BIM 650-... .
DRM 611-01
Display call module as an input
unit with display for placement
of door calls in conjunction
with BIM 650-... .
The names are indicated in
alphabetical sequence in the
display.
The DRM 611-... can also be
used in combination with the
COM 611-... in order to display
the input via the COM 611-... .
2
2
2
ERT
2
BTC 850-...
ERT
2
2
BFS 850-...
ERT
2
In order to use the control
functions or the door call
facility, 4 additional cores are
required from the input module
to the EC 602-... or
BIM 650-... .
In the case of door stations
with more than 160 call buttons, the COM 611-... or
DRM 611-... is required per
door station.
2
BNG 650-...
BIM 650-...
TR 603-...
8
Door station
2
Tö
Door area
Bus custom-fit door loudspeaker
BTLE 051-03
Bus custom-fit door loudspeaker incl. Bus call button
matrix for In-Home bus.
Integrated door release contact
(DR). Max. load 15 V AC /
30 V DC / 2 A. Connection
of existing call buttons (selfcleaning) via bus call button
matrix BRMAВ 050-..., switching
time DR fixed at 3 seconds.
For optimum mounting in an
existing on-site communication compartment, universal
mounting adapter ZTL 051-0
can be used.
BRMA 050-01
Bus call button matrix for the
connection of existing call buttons to the custom-fit door
loudspeaker BTLE 050-.../
ATLE 670-...
Max. 14 BRMA 050-... can be
connected to 1 BTLE 050-.../
ATLE 670-...
Door area
Siedle Classic
CL A xx B-01
Classic door station with different front surfaces for the
Siedle In-Home bus for flush
mounting with flush mount
housing. With one or more call
button(s), backlit name plate,
exchangeable from the front.
Door area
Select door station
CL V xx B-01
Classic door station with stainless steel front, V4A brushed,
with flush-mount housing.
Door loudspeaker, 1 to 4 call
buttons with backlit nameplates, exchangeable from the
front, colour CCD camera with
integrated infrared lighting.
STA/SBA 850-xx
Select audio door station made
of high-grade plastic with
aluminium front, for surface
mounting. With one, two
or four call button(s), backlit
nameplate, exchangeable from
the front.
The Select audio door station
with letterbox is equipped with
a call button.
STV/SBV 850-...
Select video door station made
of high-grade plastic with
aluminium front, for surface
mounting. With colour camera,
one, two or four call button(s),
backlit nameplate, exchangeable from the front.
The Select video door station
with letterbox is equipped with
a call button.
Max. 160 call buttons can be
connected. However, a bus call
button matrix BRMA 050-... is
required for each started group
of 12 call buttons.
25
Object width in m (a)
5,
0
3,8
mm
Our training and exhibition
centres will be pleased to
advise you.
See page 39
m
Application/General
Video cameras operating with
the Vario door loudspeaker or
externally in the background
provide an unobtrusive method
of surveillance in the entrance
area. Call, speech and door
release operation of the door
station. The visitor appears on
screen at one or more of the
video call stations.
m
Device description
Cameras
Possible applications include
single and multiple family
homes, private/commercial
premises, practices and surgeries, administrative buildings
etc.
Other video components for
special applications can be
combined with our devices on
request.
9,5
mm
Object distance in m (h)
Diagram showing the pick-up range of
external camera CEC 612 with image
pick-up chip 1/3”.
Connection to Siedle In-Home: Video
with bus video transmitter BVS 650-... or
bus video interfacing module
BVA 650-...
Location of the video camera
Selection of the most suitable camera
and its location is decisive to ensure
good picture quality. The camera must
not be directed towards:
mm
40,0 mm
Object distance in m (h)
If the range of the camera module is
not sufficient, external cameras such as
the CEC 612-... or KA/WG 950-... can
be used.
ca. 143 cm
ca. 84 cm
50 cm
Object width in m (a)
8,0
160 cm
MC
BC
Object width in m (a)
50 cm
m
m
64 cm
106 cm
109 cm
214 cm
3,
8
650
0
5,
83,0 mm
Diagram showing the pick-up range of
bus camera BCMC 650-... with image
pick-up chip 1/3”.
BCMC 650
horizontal
m
m
2,9
m
m
BCMC 650
vertical
• Direct backlight
• Direct sunlight
• Picture backgrounds with a high
degree of brightness
• Highly reflective walls
• Lamps or light sources etc.
Object distance in m (h)
Diagram showing the pick-up range of
the KA/WG 950-... with image pick-up
chip 1/4”.
Connection to Siedle In-Home: Video
with bus video transmitter BVS 650-... or
bus video interfacing module
BVA 650-...
Pick-up range of the camera module
BCMC 650-...
The shaded area indicates the adjustment range of the BCMC 650-...
Cameras
BCMC 650-0
Bus colour camera module for
Siedle In-Home bus: Video.
Integrated 2-step heating,
day/night switching, infrared
lighting and video signal
converter. Supply via Siedle
In-Home bus: Video, heating
supply 12 V AC, 100 mA.
CEC 612-0
External colour camera day/
night CCD video camera for
external mounting in weather
proof housing, wall arm with
ball head and internal wiring.
Connection to In-Home bus:
Video via bus video interfacing
module BVA 650-... or bus
video transmitter BVS 650-...
supply via additional line rectifier, 10,5 - 30 V DC, current
consumption max. 250 mA.
KA/WG 950-0 C
External colour CCD video
camera for external mounting
with weather proof housing
and sun shade, wall arm with
ball head and internal wiring.
Connection to In-Home bus:
Video via bus video interfacing
module BVA 650-... or bus
video transmitter BVS 650-...
supply via additional line rectifier, 20 - 30 V DC, current consumption max. 250 mA.
Using the line rectifier foot
accessory ZNF 950-0 it is possible to provide a 230 V AC
power supply.
ZNF 950-0
Line rectifier foot accessory for
the camera KA/WG 950-...,
for supplying from the 230 V
network.
BVS 650-01
Bus video transmitter in a
surface-mount housing with
cable glands for connection of
an external video camera and
a bus door loudspeaker to the
Siedle In-Home bus.
Camera
Door station
Power supply
Coaxial cable
2
BVS 650
Tö
6
6
In-Home-Bus: Video
Distribution
External camera in conjunction with
BVS 650-... at the BTLM 650-...
BVA 650-0
Bus video interfacing module
BVA 650 ... for actuation of
external video cameras without
door station to the Siedle
In-Home bus: Video
There are 2 versions available:
• BVA 650 AP-0
as surface mounted version,
integrated in a housing, protection system IP 54.
• BVA 650 UP-0
as flush mounted version, for
integration in 100 mm square
flush-mounting junction box
for use in dry indoor environments.
Camera 1
Camera 2
2
Input 1
2
BVA 650
4
BVA 650
4
Distribution
4
In-Home-Bus: Video
27
Device description
Bus telephones Audio
BTS 850-02
Standard bus telephone.
Connection at bus cores
Ta and Tb.
Calling, speech, door release
and storey call
•Door release and light button
•Internal speech communication
•11 ring tones
•Call and speech volume can
be changed in 5 steps
•Silencing button for the ring
tone
•Double assignment of the
light button and silencing
button possible.
•Integration of ZAR 850-...
accessory possible
BTC 850-02
Deluxe bus telephone.
Connection at bus cores
TaM and TbM.
Calling, speech, door release
and storey call
•Door release and light button
•Internal speech communication
•11 ring tones including chime
•Call and speech volume can
be changed in 5 steps
•Silencing button for the ring
tone
•7 keys for switching and
control functions with double
assignment facility
•7 LEDs under the buttons for
display of switching statuses
•Integration of ZAR 850-...
and ZPS 850-... accessory possible
BFS 850-02
Standard bus handsfree telephone. Connection at bus
cores Ta and Tb.
Calling, handsfree/push to talk,
door release and storey calls
•Speech/control button
•Door release and light button
•Internal speech communication
•11 ring tones
•Call and speech volume can
be changed in 5 steps
•Silencing button for the ring
tone
•Double assignment of the
light button and silencing
button possible.
•Integration of ZAR 850-...
accessory
BFC 850-0
Deluxe handsfree bus telephone intercom. Connection
at bus cores Ta and Tb.
Calling, handsfree/simplex
communication, door release
and storey calls
•Speech/control button
•Door release and light button
•Internal speech communication
•11 ring tones
•Call and speech volume can
be modified in 5 stages
•Muting button for the ring
tone
•7 keys for switching and
control functions with double
assignment facility
•Additional intercomfunctions
possible
•Integration of ZARF/
ZPSF 850-... accessory
Accessories
ZPS 850-0
Parallel switching accessory
for integration into deluxe
bus telephone BTC 850-...
Circuit board for connection
of an additional power supply.
Required in case of manual
programming from the third
BTC 850-... , with PC
programming from the fifth
BTC 850-... .
Supply 20 - 30 V DC from
NG 602-... or VNG 602-...,
current consumption max.
100 mA
ZPSF 850-0
Parallel switching accessory for
integration into deluxe handsfree bus telephone BFC 850-...
Circuit board for connection
of an additional power supply.
When programming manually,
required from the third
BFC 850-... , when programming by PC from the fifth
BFC 850-... . Supply
20 - 30 V DC from NG 602-...
or VNG 602-..., current consumption max. 100 mA.
Required for the function parallel door call, collective paging
announcement / internal
group call to more than 2 bus
telephones. When programming with BPS 650-... 4 bus
telephones.
ZAR 850-0
Interfacing relay accessory for
integration into bus telephones
BTS 850-... or BTC 850-...
Universal switching relay for
secondary signal unit, video
interfacing or switching relay.
Potential-free switching contact max. 15 V AC / 30 V DC,
1В A, switching time 0.4В secs.
– 19 mins. Supply via the
In-Home bus.
ZARF 850-0
Handsfree interfacing relay
accessory for integration into
the bus handsВ­free telephone
BFS 850-... Universal switching
relay for secondary signal unit,
video actuation or switching
relay, potential-free switching
contact. Potential-free contact max. 15 V AC / 30 V DC,
1В A, switching time 0.4В secs.
– 19 mins. Supply via the
In-Home bus.
ZTS 800-01
Table-top accessory for telephones BTS/BFS/BFC 850-...
and HTS 811-... for conversion from a wall to a table-top
unit. Slip-proof console with 2
rubber feet but without UAE 8
junction box.
ZTC 800-0
Table-top accessory for the telephone BTC 850-... and
HTC 811-... for conversion
from a wall to a table-top
unit. Slip-proof console with 2
rubber feet but without UAE 8
junction box.
29
DoorCom-Analog
DCA 650-02
DCA 650-02
DoorCom-Analog for connection of one or more door
stations to an analog PBX
extension of a telephone
system. Up to 31 call numbers
can be stored. The call can be
made using bell buttons or the
display call module from the
door station. Power supply with
12 V AC to terminals b and c,
connection to the In-Home:
Audio via terminals Ta/Tb.
The facility to utilize individual
performance features may
differ depending on the TC
system used. Please enquire
with the manufacturer of your
TC system.
DoorCom IP In-Home
DCIP 650-0
DCSF 600-0
DoorCom switching and
remote control interface, for
use in DCA 612-... and
DCA 650-...
DoorCom switching and
remote control interface, for
use in DCA 612-... and
DCA 650-...
DCIP 650-0
The DoorCom IP links the
Siedle door station to a TCP/
IP network/Intranet. As a functional unit, the DCIP 650-...
consists of the devices system
interface In-Home bus
SII 650-..., system interface
video server SIVS 610-... and
IP video server IPVS 600-...
The DCIP 650-... behaves in the
same way as an In-Home bus
system user
•One DCIP 650-... can be
connected per line
•4 software licences included
in the scope of supply
•Other licences
DCIP SC 600-... possible
Device description
Bus telephones Video
S 850-0
Siedle Scope cordless DECT
telephone with door video
function for the In-Home bus.
Comprising a base station,
cordless handset and charging
tray. Scope unites the worlds
of door communication and
public network telephony, it
is a comfort video in-house
telephone and DECT telephone
in one.
Performance features
• Individual design concept
with six design variants
• Large 5.5 cm colour display,
240 x 320 pixel, illuminated
• Handsfree function
• Charging tray with illuminated control keys (call acceptance and door release)
• 8 ring tones
• Telephone directory for
50 entries
• Caller list with 20 entries
including date and time
• Last number redial
• Optional menu language
setting
• Li polymer battery
• Battery life on standby up to
100 h
• Range outdoors up to 300 m,
indoors up to 50 m
• Doormatic
• Upgradable: Up to 8 cordless
handsets in parallel
• Operation possible with and
without Telephone system
BTSV 850-03
Standard bus telephone with
colour monitor for Siedle inhome bus
Functions:
•Calling, speech, vision, door
release and storey call
•Colour monitor 8.8 cm (3.5“)
•Door opener and light button
•Mute button for call tone
•11 call tone melodies
•Monitor button for current
picture
•Brightness and colour regulation
BTCV 850-02
Comfort bus telephone with
colour monitor for door and
internal telephony.
Functions:
•Calling, speech, vision, door
release and storey calls
•Colour monitor 8.8 cm (3.5")
•Integrated video memory for
28 pictures, upgradable with
SD card
•Door release and light button
•Keys for switching and control functions
•Internal speech communication
•display of switching statuses
•Silencing button for the ring
tone
•11 ring tones
•Call and speech volume can
be modified in 5 stages
•Monitor button for current
picture
•5-way button for video
memory and zoom function
•Video memory function (only
with additional installation)
BFSV 850-03
Standard handsfree bus telephone with colour monitor
Functions:
•Calling, hands-free/simplex
communication, video, door
release and storey call
•Speech/control button
•Door opener and light button
•Internal speech communication
•Muting button for call tone
•11 call tone melodies
•Call and speech volume
adjustable in 5 steps
•Potential-free contact for
additional signal device
•Colour monitor 3.5"
(8.8 cm)
•Monitor button for current
picture
•Brightness and colour regulation
•Direct door dialling (video
and sound)
BFCV 850-02
Deluxe handsfree bus telephone intercom with colour
monitor for Siedle In-Home bus
Functions:
•Calling, speech, vision, door
release and storey call
•Speech/control button
•Colour monitor 8.8 cm (3.5")
•Integrated video memory for
28 pictures, memory upgrade
possible using an SD card
•Door release and light button
•Buttons for switching and
control functions
•Internal speech communication
•Display of switching statuses
•Muting button for call tone
•11 ring tones
•Call volume adjustable in
5 steps
•Speech volume adjustable
5 steps
•Monitor button for current
picture
•5-way button for video
memory and zoom function
•Video memory function (only
with additional installation)
31
Accessories
Bus secondary signal
unit
BNS 750-...
BFS 850-...
2
2
BTC 850-...
SZM 850-0
Siedle Scope supplementary
cordless handset with charging
tray and plug-in line rectifier.
The SZM 850-… is a comfort
video in-house telephone and
DECT telephone in one, as an
add-on for basic package
S 850-...
Up to 8 cordless handsets can
be logged into one base station.
ZTCV 850-0
Table-top accessory for bus
telephones with colour monitor
BTCV/BFCV 850-0 as well as
BTSV/BFSV 850-03 for conversion from a wall to a table-top
unit. Slip-proof console with
2 rubber feet but without telecom socket UAE 8/8.
BNS 750-02
Bus secondary signal unit in
low-profile surface-mounted
design with loudspeaker,
volume control adjustable from
the outside and electronic call
generator, programmable in
parallel to the BTS/BFS/BTC/
BFC/BTSV/BFSV/BTCV/
BFCV 850-...
Counts as a user within the
limit of 465 units (users). Call
differentiation for storey and
door calls.
2
BTS 850-...
2
Cable size diagram with secondary
signal unit
Device description
Power supply Audio
BNG 650-0
Bus line rectifier fГјr Siedle
In-Home bus audio in switch
panel housing for power supply
to the bus users.
Optional plug-in facility for the
bus supply unit accessory
ZBVG 650-...
Relay contact for door release
and light.
Space requirement in
the distributor
Power supply Video
ZBVG 650-0
Bus supply unit accessory as a
plug-in card for integration in
bus line rectifier BNG 650-...
or bus video line rectifier
BVNG 650-... with 8-pin
Western socket for connection
of the programming interface
PRI 602-... USB.
Is required in systems with
more than one line or for programming the in-home bus via
a Windows PC and
PRI 602-... USB. Only one unit
may be installed within the
Siedle In-Home bus.
BVNG 650-0
Bus video line rectifier for
Siedle In-Home bus video in
switch panel housing for power
supply to the bus users.
Optional plug-in facility for the
bus supply unit accessory
ZBVG 650-... and bus video
line rectifier accessory
ZBVNG 650-... as a video
amplifier.
TR 603-0
Transformer in switch panel
housing, to supply supplementary components.
For every connected video
door station, a separate power
supply to the door release or
call button module lighting is
required.
ZBVNG 650-0
Bus video line rectifier accessory as a plug-in card for installation in bus video line rectifier
BVNG 650-... Required where
attenuation within a line is
> 45 dB or for the creation of a
multiple-line system with more
than one BVNG 650-...
In the case of multiple line systems, the ZBVNG 650-... must
be installed in each
BVNG 650-...
Devices
Unit width
BNG 650-...
9
BVNG 650-...
9
TR 603-...
3
NG 602-...
6
BSM 650-...
3
BIM 650-...
3
DCA 650-...
6
DCIP 650-...
6+8+5
EC 602-...
6
ECE 602-...
3
PRI 602-... USB
3
33
Switching and control devices
BSM 650-02
Bus switching module in switch
panel housing with 4 integrated relays, each with one
potential-free work contact.
Programmed functions can be
actuated using the programmable buttons of the system
users or in parallel to a door
call button to actuate an
external signalling device.
BSE 650-0
Bus switching unit with bistable
relay, suitable for mounting in
a 55 junction box.
Actuation possible via BEM,
using the programmable buttons of the system users or in
parallel to a door call button.
Power supply via the In-Home
bus
Admissible switching output:
• Light bulbs max. 1300 W
• Fluorescent lamps max.
800 W
• Twin fluorescent lamps max.
1200 W
• Parallel compensated fluorescent lamps max. 400 W
BEM 650-0
Bus input module for mounting
in a 55 junction box with an
input for tripping switching
functions/transmitting messages at the In-Home bus.
Activation possible via potential-free contact or 4 - 30 V DC,
10 mA.
Power supply via the In-Home
bus
Bus distributor audio
Bus distributor video
BAA 650-0
Bus audio decoupler, suitable
for mounting 55 junction box,
for connection of pure audio
components to the In-Home
Video bus, e.g. BTS, BFS, BTC,
BFC, BTLM/BTLE without video,
BNS, BSM, BIM etc.
BVVS 650-0
Symmetrical bus video distributor with 2 outputs, suitable for mounting in a 55
junction box, for creation of a
tree structure or in the case of
several risers.
BVVU 650-0
Asymmetrical bus video distributor, suitable for mounting
in 55 junction box, for coupling
one bus video transmitter
BVS 650-... / BCMC 650-...
each
Vario bus
Switching and control devices
Information on
programming
General
Programming for the In-Home
bus is described in the System
Manual provided with the
BNG/BVNG 650-... and can
be performed manually, using
Plug+Play or with PC.
For programming with the PC,
the interface PRI 602-... USB
with software BPS 650-... from
V 2.00 is required.
EC 602-03
Entrance controller in switch
panel housing for code lock
module COM 611-..., electronic
key reading module
ELM 611-... or fingerprint
module FPM 611-...
Display-supported programming of integrated buttons, or
by means of PC software via
additional programming interface PRI 602-... Electronic evaluating circuit with 2 switching
outputs, extendable to 8 with
ECE 602-..., 2 control inputs for
time-controlled access rights.
ECE 602-0
Entry controller extension
in switch panel housing.
Upgrades the EC 602-… by a
further 6 working contacts.
PRI 602-01 USB
The programming interface
PRI 602-... USB in a switch
panel housing connects a
Windows PC via the USB port
to the Siedle In-Home bus.
Connection to the line rectifiers
BNG 650-... and BVNG 650-...
via ZBVG 650-...
The bus programming software
BPS 650-... is included in the
scope of delivery. Interface to
the Siedle In-Home bus via
8-pin Western socket or via
screw terminals.
Only one PRI 602-... USB can
be connected to a PC.
PRS 602-0
Programming software suitable for programming the RC/
RCE 602-... or EC/ECE 602-...
in conjunction with an IBMcompatible PC via an RS 232 or
USB interface.
For programming the RC/
RCE 602-... , a chip card reader
can also be used.
System requirements:
Windows PC, Win 2000,
Win XP/Vista (32 Bit)
VBPS 602-01
Vario bus logging software for
monitoring control functions
executed via an EC/ECE 602-...,
e.g. access control.
The programming interface
PRI 602-.../PRI 602-... USB is
required.
System requirements:
Windows PC, Win 2000,
Win XP/Vista (32 Bit)
35
37
Siedle exhibition centres
Bahrain
Intercom Gulf
P.O. Box 1054
Manama
Tel. +973 17 732251
Fax +973 17 731840
www.arabco.me
info@arabco.me
Iceland
Smith & Norland
NГіatГєni 4
105 Reykjavik
Tel. +354 5203000
Fax +354 5203011
www.sminor.is
sminor@sminor.is
China
Nixon Technology
Company Ltd.
1/F, Glorious Sun Group Building,
97 How Ming Street,
Kwun Tong, Kowloon,
Hong Kong
Tel. +852 28922188
Fax +852 28319973
www.nixon.hk
nixon@nixontcl.com
Lebanon
Unimec International
ABC Building, 5th Floor,
Hamra Street, Beirut,
Box 113-7209, Lebanon
Tel. +961 1 355034
Fax +961 1 740054
www.unimec.com.lb
info@unimec.com.lb
Czech Republic
EST s.r.o
Pod PekГЎrnami 338/12
19000 Praha 9
Finland
Siedle Nordic A/S
Finland
Rajatorpantie 41 C
01640 Vantaa
Tel. +358 40 8221302
Fax +358 9 5863570
www.siedle.fi
info@siedle.fi
Greece
Expo SA.
13 Amaliados Str.
14564 - N. Kifisia
Tel. +30 210 800 24 87-488
Fax +30 210 6250804
www.expo.gr
info@expo.gr
Sweden
Siedle Nordic A/S
Sverige
Solna Strandväg 78
171 54 Solna
Tel. +46 77 1188 890
Fax +46 850521010
www.siedle.se
info@siedle.se
USA
Siedle Security
Systems of America LLC
750 Parkway
Broomall, PA 19008
Toll-free-no. 0800 874 3353
Tel. +1 610 3539595
Fax +1 610 3539716
www.siedleusa.com
info@siedleusa.com
Singapore
Nixon System(S) Pte. Ltd.
1 Tannery Road
#07-04 One Tannery
Singapore 347719
Tel. +65 63526460
Fax +65 63526461
www.nixontcl.com
siedle_spore@siedle.com.sg
Norway
Siedle Nordic A/S
Avdeling Norge
Gamle Drammensvei 48
1369 Stabekk
Tel. +47 6711 0607
Fax +47 6711 0255
www.siedle.no
info@siedle.no
Spain
SiedSpain S. L.
CapitГЎn Haya 1, Planta 15
28020 Madrid
Tel. +34 91 6612322
Fax +34 91 1413441
www.siedle-spain.net
info@siedle-spain.net
Portugal
TEV2
Distribuicao de Material Electrico, Lda
Zona Industrial da Maia I - Sector VII Rua D - Lote 137
4470-595 Maia
Tel. +351 2 29478170
Fax +351 2 29485164
www.tev.pt
info@tev.pt
United Kingdom
Intercom Elite Limited
2nd Floor Titan Court
3 Bishop Square
Hatfield
Hertfordshire AL10 9NA
Tel. +44 870 3516082
Fax +44 703 1152481
www.intercomelite.com
info@intercomelite.com
Russia
SiedCom LLC
Derbenyovskaya street, 20, building 12
115114, Moscow
Tel./Fax: +7 495 926-01-05
www.siedle.ru
info@siedle.ru
U.A.E.
Al Mazroui – ICAS (L.L.C)
P.O.Box : 77391, Dubai, U.A.E
Garhoud, Arcade Building opposite
to Al Tayer Motors - Office 105,
Dubai, U.A.E
Tel. +971 4 282 6070
Fax +971 4 286 5626
www.almazrouicas.com
icasdxb@emirates.net.ae
39
3
S. Siedle & Söhne
Postfach 1155
78113 Furtwangen
BregstraГџe 1
78120 Furtwangen
Telefon +49 7723 63-0
Telefax +49 7723 63-300
www.siedle.de
info@siedle.de
В© 2011/03.11
Printed in Germany
Best.-Nr. 0-1108/084712 EN
Download